Source-listed values: Material: Aluminum Alloy; 储藏温度: -30℃~70℃. Check the source and configuration notes below.

34 published fields · Specification data available · Reviewed 8 October 2026

LOCSTAR LS-C17 — source-published image

Product artwork

LOCSTAR LS-C17 — model-specific selection graphic; Door thickness (technical table): 38–60 mm; Working voltage: 4节5#电池(4.2-6.5V); Unlocking ways: IC card/mechanical key; Power supply: 4 AA alkaline batteries.

Parameters from the linked sources

Source artwork. Check the ordered finish and configuration against the supplier’s documents. Original product detail

Product advantages and buyer fit

  • The mechanical key provides backup entry alongside the listed electronic credentials.

What the published attributes mean for your project

Door fit and replacement cost

Mortise endurance claim: Around 200,000 cycles

Compare these measurements with your existing doors. Before covering old cut-outs or changing the mortise, check the matching drawing and fit a sample.

Credentials and front-desk workflow

Unlocking ways: IC card/mechanical key

Check that the stated configuration fits your credentials and staff workflow. Test checkout and lost-credential handling.

Power and maintenance planning

Working voltage: 4节5#电池(4.2-6.5V)

Plan consumables, service access and failure recovery around the stated power supply and endurance conditions.

Published product attributes

AttributePublished valueSource
Unlocking waysIC card/mechanical keyPublished product detail
MaterialAluminum AlloyPublished product detail
ColorBlackPublished product detail
Warranty2 yearsPublished product detail
Weight3KGPublished product detail
Product categoryHotel access lockPublished product detail
门锁类别无线射频感应门锁Published product detail
低压报警4.4V(±0.2V)Published product detail
电子钥匙Mufare 1 S50 卡Published product detail
Operating temperature-20℃~55℃Published product detail
国际标准ISO14443-APublished product detail
储藏温度-30℃~70℃Published product detail
Working voltage4节5#电池(4.2-6.5V)Published product detail
Operating humidity15%RH~93%RHPublished product detail
开门功耗≤200mA持续时间≤0.2秒Published product detail
可靠性平均无故障操作≥30000次Published product detail
电池开门寿命≥10000次Published product detail
机械寿命正常开门操作≥100000次Published product detail
静态功耗≤40μAPublished product detail
Product category (source 57773dd5)Chinese domestic product portfolioPublished product detail
Catalogue variantC17Manufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Product category (source 5b5dbbfd)RFID hotel door lockManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Unlock methodsMifare S50 card (13.56 MHz) and mechanical keyManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Material (source 5b5dbbfd)Aluminium panels; stainless-steel mortise latch; alloy keyManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Power supply4 AA alkaline batteriesManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Battery endurance claimAround 10,000 openings; more than one yearManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Mortise endurance claimAround 200,000 cyclesManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Door thickness (technical table)38–60 mmManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Static current<40 µAManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Dynamic current≤150 mAManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Working temperature−20 to 55 °CManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Working humidity16–93% RHManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Audit trail (as printed)800 recent unlock messagesManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.
Low-voltage warning (as printed)5.0 V (+0.2 V); catalogue claims at least 100 subsequent unlocksManufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations.

Documents and installation guidance

  1. LOCSTAR 2024 hotel-lock technical table and dimension drawing

    Manufacturer catalogue printed page 20, exact printed variant C17; technical table and diagram visually inspected 2026-10-08. Data applies to this catalogue variant only, not all products sharing its numerical model stem. Values are manufacturer declarations. Catalogue, not operating or installation manual.

Configuration and procurement checks

Source and variant differences

  • Published values for Product category differ between source listings; confirm the ordered configuration.
  • Published values for Product category differ between source listings; confirm the ordered configuration.
  • Published values for Material differ between source listings; confirm the ordered configuration.
  • Same page prose says door thickness 38–55 mm while technical table says 38–60 mm; confirm exact installed mortise/door configuration.
  • Catalogued endurance and voltage values may differ from current product-page values; do not silently merge across hardware revisions.

Unpublished or unverified items

  • Model-specific installation manual and Malaysian approval not verified.
  • Do not infer room count from a local card capacity.
  • Installation manual: pending.
  • Domestic and export model equivalence is not assumed.
  • Current exact variant availability, Malaysian approval and per-model installation manual not verified.

Malaysia project acceptance

  1. Check the ordered product against your measured door or accessory schedule, then test an installation sample.
  2. Before rollout, test the actual software and what happens at checkout, when a credential is lost and when power fails.
  3. Ask the quotation to name the installer and set out the applicable local documents, warranty and service coverage.