HOTEL ACCESS · MALAYSIA SELECTION

Rixiang Unlock by IC/ID cards storage locker lock Sauna Spa Gym Electronic Cabinet Lock

Source-listed values: material: Zinc Alloy; Package dimensions: 180*175*55mm. Check the source and configuration notes below.

23 published fields · Specification data available · Reviewed 7 October 2026

Rixiang Unlock by IC/ID cards storage locker lock Sauna Spa Gym Electronic Cabinet Lock — source-published image

Product artwork

Rixiang Unlock by IC/ID cards storage locker lock Sauna Spa Gym Electronic Cabinet Lock — model-specific selection graphic; Unlocking way: card; Package dimensions: 180*175*55mm; Battery life: More than 15 months; Operating temperature: -30℃~80℃".

Parameters from the linked sources

Source artwork. Check the ordered finish and configuration against the supplier’s documents. Original product detail

Product advantages and buyer fit

  • Before choosing a configuration, check how the listed credentials fit guest and staff access.

What the published attributes mean for your project

Door fit and replacement cost

Product Size: 40*40*32mm

Compare these measurements with your existing doors. Before covering old cut-outs or changing the mortise, check the matching drawing and fit a sample.

Credentials and front-desk workflow

Opening the door: If the door lock is not enough to open it, you can open it by the external power supply connector panel. Use only the fifth alkaline battery, you can not use the rechargeable battery.

Check that the stated configuration fits your credentials and staff workflow. Test checkout and lost-credential handling.

Power and maintenance planning

Battery life: More than 15 months

Plan consumables, service access and failure recovery around the stated power supply and endurance conditions.

Published product attributes

AttributePublished valueSource
Double open carddouble-click twice with the management card. When the blue LED is flashing, start the server board. Once the blinking stops, you can use the host card and the server board to open the door. (Note: To configure multiple server adapters, you must configure them continuously after the management card emits two beeps.)Published product detail
>=500 Pieces$7.90Published product detail
Opening the doorIf the door lock is not enough to open it, you can open it by the external power supply connector panel. Use only the fifth alkaline battery, you can not use the rechargeable battery.Published product detail
Clear all informationThrough the small hole in the back of the lock cylinder, use the tool button for 2 seconds, a blue light will flash and all information will be erased once the light goes out. (After emptying, press the first step to reset and use it.) After continuously detecting 5 times with the management card, drip 2 sounds long and flashes twice.Published product detail
Total mapcontinuously detect 4 times with the management map. When the blue LED blinks, the entire card is detected. Once the blue light stops blinking, the entire card can open the door. (Note: Set according to customer needs.)Published product detail
Sensitive should beits detection distance is very large, it has a contactless card EM, the detection distance is greater than 20 mm.Published product detail
Types ofEM:115Published product detail
package1piece/boxPublished product detail
colourSilver/GoldenPublished product detail
usageDrawer, wardorbe,cabinetPublished product detail
shapeSquarePublished product detail
CertificationCE FCC ROHSPublished product detail
Product Size40*40*32mmPublished product detail
materialZinc AlloyPublished product detail
Logo printingSupport customsizedPublished product detail
Warranty1 YearPublished product detail
Package dimensions180*175*55mmPublished product detail
Master card capacity1PCSPublished product detail
Guest card capacity16PCSPublished product detail
Unlocking waycardPublished product detail
Battery lifeMore than 15 monthsPublished product detail
Operating temperature-30℃~80℃"Published product detail
Product categoryCabinet / locker lockPublished product detail

Qualification scope

Request the model-specific certificate number, test report and applicable door-assembly documentation.

Documents and installation guidance

Technical document check

品牌尚未公布

No matching public technical-document link was found in the sources checked.

Document search: 2026-10-14. No publicly verified model document link in searched range.

Official document or support entry — Official Rixiang manufacturer website

Sources and search scope

Bounded official support/download center plus representative exact-model searches; existing documented records excluded.

Configuration and procurement checks

Unpublished or unverified items

  • Operating manual: pending.
  • The public listing gives a product name, but no unique SKU or model code.

Malaysia project acceptance

  1. Check the ordered product against your measured door or accessory schedule, then test an installation sample.
  2. Before rollout, test the actual software and what happens at checkout, when a credential is lost and when power fails.
  3. Ask the quotation to name the installer and set out the applicable local documents, warranty and service coverage.

Original evidence pages

  1. Exact product / document source 1

Reviewed 7 October 2026.