BONWIN Hotel RCU Room Control Unit System

Source-listed values: Control cabinet dimensions: 500 × 400 × 90 mm; Control cabinet material: 1 mm painted steel plate. Check the source and configuration notes below.

19 published fields · Specification data available · Reviewed 2026-10-12

BONWIN Hotel RCU Room Control Unit System — source-published image

Product artwork

BONWIN Hotel RCU Room Control Unit System — model-specific selection graphic; Power module DC output: 12 V ±2 V; <5 A; Dimming module working voltage / current: DC 12 V; <200 mA; Control cabinet dimensions: 500 × 400 × 90 mm; Thermostat external dimensions: H86 × W86 × D13 mm.

Parameters from the linked sources

Source artwork. Check the ordered finish and configuration against the supplier’s documents. Original product detail

What the published attributes mean for your project

Door fit and replacement cost

Control cabinet dimensions: 500 × 400 × 90 mm

Compare these measurements with your existing doors. Before covering old cut-outs or changing the mortise, check the matching drawing and fit a sample.

Credentials and front-desk workflow

System communication: TCP/IP

Check that the stated configuration fits your credentials and staff workflow. Test checkout and lost-credential handling.

Power and maintenance planning

Power module AC input: 110–220 V ±15%; 50–60 Hz

Plan consumables, service access and failure recovery around the stated power supply and endurance conditions.

Published product attributes

AttributePublished valueSource
System communicationTCP/IPSystem overview; not a per-lock protocol claim.
Temperature reporting interfaceRS485 to iPad-control systemTemperature-monitoring workflow section; current client implementation unverified.
Indoor temperature sensorNTCSystem sensing description.
Control cabinet dimensions500 × 400 × 90 mmBWRC388 RCU cabinet assembly section; source spelling varies BWRCU388/BWRC388.
Control cabinet material1 mm painted steel plateRCU cabinet assembly section.
Power module AC input110–220 V ±15%; 50–60 HzSeparate power-supply module; not the input voltage of every component.
Power module DC output12 V ±2 V; <5 ASeparate power-supply module; stated current and protection claim, not whole-system consumption.
Lighting module working voltage / currentDC 12 V; <300 mALighting/output-control module paragraph; not dimmer or thermostat consumption.
Lighting relay output claim10 ALighting module relay; exact loads and channel configuration need confirmation.
Dimming module working voltage / currentDC 12 V; <200 mASCR dimming-module paragraph; not the complete RCU consumption.
Dimming module output claim5 A per channel; dimming range 1–100Separate dimming-module paragraph; load type/rating must be confirmed.
Thermostat working voltage / currentDC 12 V ±3 V; <25 mAFinal thermostat parameter table; not the RCU cabinet or power-module rating.
Thermostat temperature control range10–30 °CFinal thermostat parameter table.
Thermostat stated accuracy±1 °CFinal thermostat parameter table; manufacturer claim, independent test unavailable.
Thermostat compensation range−9 to +9 °C; default −1 °CFinal thermostat parameter table.
Thermostat communicationRS485; 9600 bpsFinal thermostat parameter table.
Thermostat working environment0–55 °C; max 90% RH, non-condensingFinal thermostat parameter table.
Thermostat external dimensionsH86 × W86 × D13 mmFinal thermostat parameter table.
Control modeManual and automatic; manual priority statedRCU system function paragraph.

Documents and installation guidance

Technical document check

品牌尚未公布

No matching public technical-document link was found in the sources checked.

Document search: 2026-10-14. Official Brochure & Manual pages 1–3 checked; public BW883 family setup guide and explicit variant parameter sheets verified.

Official document or support entry — official support/download center

Sources and search scope

Search scope: official document centres and official-domain results for records without a registered document link.

Configuration and procurement checks

Unpublished or unverified items

  • Exact configuration/order code and installation manual require supplier confirmation
  • Exact ordered module list, channel ratings, model spelling, wiring drawing and Malaysia electrical applicability require supplier confirmation.

Malaysia project acceptance

  1. Check the ordered product against your measured door or accessory schedule, then test an installation sample.
  2. Before rollout, test the actual software and what happens at checkout, when a credential is lost and when power fails.
  3. Ask the quotation to name the installer and set out the applicable local documents, warranty and service coverage.